epr spectrometer modernization

EPR Spectrometer Modernization & Upgrade

Modernize and upgrade your old EPR instrument for cutting-edge EPR research

 

This EPR Modernization and Upgrade service will bring you features including:

Higher Sensitivity: Ultra-low noise microwave source and signal detection technology

Better Resolution: Precise magnetic field control technology

Excellent Compatibility: Compatible with a wide range of EPR spectrometers

Fast Delivery: Complete delivery of the modernized hardware within 2-6 months

High-Quality Service: On-site installation and 2-year warranty

 

★ Email us for more details: info@ciqtek.com

▶ CIQTEK EPR Spectrometer Modernization and Upgrade Pathways

  • CIQTEK EPR Spectrometer Upgrade Pathways

Microwave Bridges

CIQTEK EPR Spectrometer Upgrade -  CW Microwave Bridge Features

CW Microwave Bridge Features

X-band

 • Microwave frequency range: 9.2 to 9.9 GHz
 • Max output microwave power in leveled mode: 200 mW
 • Microwave attenuator: 0 to 60 dB in 1 dB steps
 • Support automated and manual tuning
 • Modernizable to Q-band
 • Size: 85 × 62 × 18 cm

Q-band

 • Microwave frequency: 33.7 to 34.4 GHz
 • Max output microwave power: 100 mW
 • Microwave attenuator: 0 to 50 dB
 • Size: 65 × 62 × 20 cm

CIQTEK EPR Spectrometer Upgrade -  Pulsed microwave amplifier features

Pulsed Microwave Amplifier Features

Solid-state amplifiers have the same linearity and intermodulation distortion as traveling-wave tube amplifiers. Still, they are smaller, have a longer life, and do not require high-voltage power supplies or periodic operation.

X-band

 • Microwave amplifier power: 500 W
 • Size: 43 X 35 X 15 cm

Q-band

 • Solid-state power amplifier power: 200 W
 • Size: 45 × 40 × 16 cm


▶ EPR Spectrometer Console & Magnetic Power Supply

CW Part Features

1. Magnetic Field Controller: Magnetic field stability in sample region: 10 mG/hour; Operating range: -0.1 to 1.8 T

2. Digital Lock-in Detection

3. Ultra Stable Magnet Power Supply

4. Modulation Frequency Range: 0.5 to 120 kHz

 

CIQTEK EPR Spectrometer Upgrade -  Pulsed Part features

Pulsed Part Features

Data Acquisition Unit

 • Number of channels: 2
 • Sampling rate: 1 GHz
 • Supports internal and external trigger modes

Pulse Generator

 • 12 digital channels
 • Time resolution: 0.05 ns

Resonators

▶ High-Q Resonator

1. Cavity resonance frequency: 9.5 to 9.9 GHz

2. Unloaded Q ≥ 16,000 (critically coupled)

3. Maximum modulation field amplitude: 20 Gauss

4. Compatible with the nitrogen and helium variable temperature system

5. Autotune available

CIQTEK EPR Spectrometer Upgrade - High-Q Resonator

Resonator width: 50 mm
Optical window: Ø 5 mm, compatible with optical fiber
Maximum sample access: Ø 10 mm


Dual Mode Resonator

1. Cavity resonance frequency:9.6 to 10 GHz (perpendicular mode), 9.4 to 9.8 GHz (parallel mode)

2. Maximum modulation field amplitude: 10 Gauss

3. Compatible with the nitrogen and helium variable temperature system

CIQTEK EPR Spectrometer Upgrade -  Dual Mode Resonator

Resonator width: 46 mm
Optical window: Ø 5 mm, compatible with optical fiber
Maximum sample access: Ø 10 mm


PW-4201-DR Pulsed Resonator

1. Cavity resonant frequency: 9.4 to 9.8 GHz

2. Resonator bandwidth: 400 ± 40 MHz

3. Detection dead time: ≤ 100 ns

4. Compatible with the nitrogen and helium variable temperature system

CIQTEK EPR Spectrometer Upgrade - PW-4201-DR Pulsed Resonator

Sample rod: 423 mm
Optical window: 5 × 12.5 mm
Flange: KF50
Available sample tube diameter: 3 mm or 4 mm OD


ENDOR Pulsed Resonator

1. Cavity resonant frequency: 9.4 to 9.8 GHz

2. Resonator bandwidth: 400 ± 40 MHz

3. Detection dead time: ≤ 100 ns

4. Compatible with the nitrogen and helium variable temperature system

CIQTEK EPR Spectrometer Upgrade - ENDOR Pulsed Resonator

Sample rod: 423 mm
Optical window: 5 × 12.5 mm
Flange: KF50
Available sample tube diameter: 3 mm or 4 mm OD


Cryogenic Systems

▶ Liquid Helium Continuous-Flow Cryogenics System

CIQTEK EPR Spectrometer Upgrade - Liquid Helium Continuous-Flow Cryogenics System

Controllable Temperature Range (Sample Area): Standard: 4.4–300 K; Optional: 3.2–300 K

Temperature stability: ± 0.1 K (in liquid helium temperature zone)
Rapid cooling: cooling time < 30 minutes
Low liquid helium loss
Easy installation


▶ Liquid Helium-Free Dry Cryogenic System

CIQTEK EPR Spectrometer Upgrade - Liquid Helium-free Dry Cryogenic System

Controllable temperature range of sample area: 4 to 300 K
Temperature stability: ± 0.1 K (in liquid helium temperature zone)
Wider temperature control range
Stable and easy operation
Rapid temperature recovery after sample change (<30 minutes)
Extremely low operating costs

  • CIQTEK EPR Spectrometer Upgrade - CW-type Cryostat
    CW-Type Cryostat

    Compatible with High-Q resonator and Dual-mode resonator.

  • CIQTEK EPR Spectrometer Upgrade - L-type Cryostat
    L-Type Cryostat

    Compatible with the DR pulsed resonator and the ENDOR resonator.
    Cavity ID: 45 mm (wet system); 43 mm (dry system)


Liquid Nitrogen Variable Temperature System

CIQTEK EPR Spectrometer Upgrade - Liquid Nitrogen Variable Temperature System

Controllable temperature range of the sample area: 93 to 573 K
Temperature stability: ± 0.2 K
Rapid cooling: cooling time < 30 minutes
Compatible with high-temperature testing

Leave A Message
Please feel free to contact us for more details, request a quote or book an online demo! We will reply you as soon as we can.
Submit
Related Products
benchtop EPR spectrometer

Compact X-Band EPR with high sensitivity and easy operation — ideal for chemistry, catalysis, and materials research.   CIQTEK EPR200M is a compact benchtop electron paramagnetic resonance (EPR) spectrometer designed for the detection and analysis of free radicals, transition metal ions, and paramagnetic defects. It allows researchers to monitor chemical reactions in real time and gain deeper insights into materials with high sensitivity and stability.   Trusted by Researchers Worldwide >> 300+ EPR Systems Installed | 170+ Scientific Publications <<   Contact Our Experts > U.S. & North America: info.usa@ciqtek.com > International & Other Regions: info@ciqtek.com

Learn More
CW EPR spectroscopy

The CIQTEK EPR300 Electron Paramagnetic Resonance (EPR) Spectrometer incorporates the latest microwave technology and an ultra-high-performance signal processing unit, significantly enhancing detection sensitivity and signal-to-noise ratio to an unprecedented level. It enables precise detection and analysis of unpaired electron signals even at extremely low spin concentrations, providing a novel approach for exploring microscopic physical and chemical properties of low-concentration substances such as free radicals and metal ions.   Additionally, the EPR300 supports easy upgrades from X Band to Q Band, achieving higher g-value resolution, which is advantageous for detecting anisotropic samples. The EPR300 establishes a solid experimental foundation for cutting-edge research in life sciences, materials science, chemistry, and physics, driving scientific discoveries to new milestones.

Learn More
x band pulse electron paramagnetic resonance

CIQTEK X-band pulse electron paramagnetic resonance (EPR or ESR) spectrometer EPR100 supports both continuous-wave EPR and pulse EPR functions. In addition to supporting conventional continuous-wave EPR experiments, the EPR100 can also finely control and measure electron spin quantum states using specific pulse sequences. This enables pulse EPR tests such as T1, T2, ESEEM (electron spin echo envelope modulation), HYSCORE (hyperfine sublevel correlation), etc.   The EPR100 instrument offers a comprehensive range of optional accessories, such as ENDOR, DEER, TR-EPR, and AWG modules, which fully meet the requirements of all current pulsed EPR experimental modes. When paired with a variable temperature system, it enables the detection of paramagnetic substances at ultralow temperatures.   Pulsed EPR spectroscopy provides higher spectral resolution, revealing the hyperfine interactions between electrons and nuclei and delivering more detailed structural information. This capability is irreplaceable and crucial in scientific research areas such as materials science, biomolecular structure analysis, etc.